Veris Homepage  
 
800.354.8556 / +1.503.598.4564
 
  Search
[Login]
Order Summary

There are no items in the cart.
 
Customers also ordered
Home >
U006-0003
U006-0003 - $2,529.41 EA
Quantity:
  • Overview
  • Series Specifications
Together with our SC water detection sensing cable, the LD5100 panel detects and reports the presence and exact location of water and other conductive fluids. When any conductive fluid comes in contact with the patented cable, the monitoring panel quickly pinpoints the location of the leak, triggering an alarm and displaying the location.
Features
  • Adjustable leak and contamination alarm thresholds to prevent false alarms due to high humidity...high detection accuracy
  • RS-232 port allows configuration with PC
  • 4-20mA output interfaces with external building management systems (BMS)...application flexibility
  • Input Power 100/120/230-240VAC @ 500mA max, 50/60Hz
Inputs:
  • Water Leak Detection Cable Requires 15ft. (4.5m) leader cable kit (LC-Kit)
  • Maximum Length 5,000ft. (1,524m)
  • Detection Accuracy ± 2ft (0.6m)+ 0.5% of the cable length
  • Detection Repeatability ± 2ft (0.6m) + 0.25% of the cable length
  • Detection Response Time 5-990sec ±2sec, software adjustable in 5 sec increments
  • Analog Output 4-20mA Loop Powered, 18-36VDC, RL = 500? max.
  • Relay Output 2 Form C Leak Relays, 2 Form C Cable Break Relays; 1A @ 24VDC, 0.5A resistive @ 120VAC; configurable for supervised or non-supervised, latched or non-latched
Communications Ports:
  • RS-232 9600 baud, No parity, 8 data bits, 1 stop bit
  • RS-485 1200, 2400, 9600, or 19200 baud (selectable); No parity, 8 data bits, 1 stop bit
Protocols:
  • Terminal Emulation (RS-232) VT100 compatible
  • Modbus (RS-485) Slave; RTU Mode; Supports function codes 03, 04, 06, and 16
  • Alarm Notification Audible Alarm 85dBA @ 2ft. (0.6m); re-sound 0-999min
Logging Capabilities:
  • Event Log Last 100 events
  • Trend Log Cable current level every day, for the last 288 days
  • Login Security :
    • Terminal Emulation Access None
    • Display Access 1 Administrator (password for configuration, no password required to view panel status)
    • Front Panel Interface Graphic, 160 x 160 resolution, backlit LCD; 1 bi-color Power/Status (green=power on, red=alarm)
    Operating Environment:
    • Temperature 0° to 50°C (32° to 122°F)
    • Humidity 5% to 95% RH, non-condensing
    • Altitude 15,000ft. (4,572m) max.
    • Storage Environment -20° to 70°C (-4° to 158°F)
    • Weight 10 lbs. (4.53kg)
    • Mounting Vertical wall mount
    • Certification CE; ETL listed: conforms to UL 61010A, EN 61010-1; CAN/CSA C22.2 1010-02; RoHS Compliant